Eight things to remember when re-starting compressed-air systems

As UK manufacturers begin to return to work following the turmoil caused by the human coronavirus (COVID-19) pandemic, General Manager at BOGE Compressors, Mark Whitmore, shares his top tips to ensure the smooth re-start of compressed-air systems.

As the UK begins to emerge from lockdown and returns to work, many of us are experiencing trouble with our vehicles. Flat batteries, sticking brakes and ruined paintwork are all issues associated with cars that have been standing idle for months on end. Similarly, those parts of the manufacturing sector that have been shut down or have been running at low volumes are having teething troubles as they begin to re-start production.

As most engineers will know, machinery is at its most reliable when it runs continuously and is maintained properly. Few machines, if any, will work well if they are shut down for lengthy periods of time. Restarting this machinery can often be a difficult process and, if handled incorrectly, can result in unexpected failures. This is especially true of compressors. Extended periods of inactivity can cause a number of issues that, if left unchecked, can seriously compromise the performance of these vitally important machines.

If you are about to reopen your facility after an extended break, there are a number of checks you should carry-out on your compressed-air system before starting it back up.

Initial checks

The first step in returning your compressed air plant to operation will always be a simple visual check to ensure that the equipment is intact and free of obstructions. Equipment must be isolated from all sources of power prior to starting these checks.

Check for oil leaks

During extended periods of shut down, there is an increased risk of oil leaks developing. When hoses and fittings cool down, they can become brittle and when the machine restarts, they can then fracture. A visual check of the compressed air system should quickly flag-up the presence of oil where it should not be, thereby confirming that pipework has been degraded. 

Check the oil quality

There is also a chance that the quality of the oil has deteriorated because it has sat still for too long. It can become dirty, which affects the performance of the compressor. Operators should therefore check for any discolouration in the oil in the tank, or for any particles floating in it. To carry-out a more comprehensive check, operators should contact their service provider so that it can undertake analysis of oil samples. 

Check the drive belts

The drive belts are another component that may have suffered from sitting still. The tension of the belts should be checked and if any visible cracks in them are identified they should be changed. 

Perform an insulation test on the motor

On larger units, it might be worthwhile to perform an insulation test on the motor. When a compressor has been operating in a warm climate and is then shut down and cools, moisture can collect inside the motor. This can cause the motor to short circuit when it is re-started. 

Re-prime the air-end

Following a stoppage of more than two months, it may be necessary to re-prime the air-end. To do this, a small amount (about 200ml) of oil should be added to the suction controller prior to starting the compressor. This oil should be the same grade as that already used in the machine, different grades and brands should never be mixed.  Once the oil has been applied through the suction controller, the air-end should be rotated by hand in the opposite direction to the markings first, then turned ten times in the correct direction, this ensures that the air-end is lubricated evenly when started.

Get up to pressure

It is best to start air treatment equipment at operating pressure, as low pressure/high velocity air can cause a host of problems. Drying equipment will take time to reach the correct dew point; this equipment should be pressurised and switched on some time before production resumes, ideally the day before. If possible, start compressors with the outlet to the main receiver closed and allow this to come up to operating pressure, before slowly opening the outlet valve to equalise the system.

Power-up controllers

Where an external controller is used, this should be powered-up prior to starting any compressor.

By following these few simple steps, the re-start of a compressor should be trouble-free. It is important to note, however, that these checks should only be carried out by qualified and authorised personnel  and  should they reveal any significant problems – the service provider should be contacted so that it can provide assistance in rectifying them.

www.boge.co.uk

http://uk-boge-5099433.hs-sites.com/reduce-food-recall-risks-0

Related Articles

Tip top compressed air

Compressed air is said to be responsible for approximately 10 per cent of the power usage in the UK and other mature economies. Beko…

Taking care with compressed air

Compressed air is the UK’s fourth utility, and as such it is widely used in industry for many purposes. Like other utilities…

Making light work of compressed air

Consolidating its smaller sites into a single, 7,500m2 factory unit has provided PRG, one of the UK’s largest theatrical lighting…

The next big thing in compressed air systems

Thirty five years ago the salesmen selling compressed air generation and treatment equipment had few tools at their disposal. Many systems…

BOGE publishes new guide to oil-free compressed air

BOGE Compressors, a leading supplier of industrial compressed air systems, has published a comprehensive new guide to oil-free compressed…

Production efficiency is all in the air

Manager of Atlas Copco Compressors oil-free air division Paul O’Neill, outlines how to select the right air treatment equipment to…